ALDERON 7013 Alarm Panel, 11.1 V Input

Part #164825

MFG #7013

164825_1287_ALDERON_7013.jpg

ALDERON 7013 Alarm Panel, 11.1 V Input

Part #164825

MFG #7013

Sign In to See Your Price

ALDERON 7013 Alarm Panel, 11.1 V Input

Part #164825

MFG #7013

Item Features
  • Power LED - A green LED illuminates (solid) on the front of the alarm panel to indicate the power is on..
  • Alarm LED - During a level alarm condition, the red alarm LED will illuminate (solid) on the front of the alarm panel..
  • Alarm Buzzer - The alarm buzzer will annunciate (solid) in addition to the visual indication provided by the red level alarm LED during an alarm condition.
  • Alarm Test Pushbutton - Press the pushbutton to test the alarm to ensure proper operation. The buzzer should annunciate, alarm LED should illuminate, and auxiliary contacts should activate..
  • Alarm Silence Pushbutton - Press the pushbutton to silence the buzzer during an alarm condition. The alarm LED remains illuminated until the alarm condition has been cleared and the alarm panel will auto reset for the next alarm cycle.
  • Sensor Inputs - Connect a field installed sensor to the terminals from the monitoring area.
  • Auxiliary Contacts - Interface with an external device including BAS systems and phone dialers. The contacts (normally open) are rated 24VDC at 500mA maximum.
  • Secondary Alarm Device Inputs - Provides a secondary remote alarm notification (Alderon indoor/outdoor LED strobe beacon)..
  • Battery Backup - Install a 9VDC battery (not included) for battery backup during power outages. The power LED will not illuminate during battery backup mode to conserve battery power..
  • Panel Access - Pull the cover off to access the panel, includes an open wiring compartment to safely route wires while connecting sensors and auxiliary dry contacts..
  • 120VAC, 50/60 Hz Primary power.
  • 11.1VDC, 500mA maximum Circuit board primary power.
  • 9VDC, standard 9VDC battery (battery backup; not included) offers protection during power outages Circuit board secondary power.
  • Test/Silence switches, automatic buzzer reset.
  • Alarm auxiliary contacts.
  • Connect a field installed sensor to the terminals from the monitoring area.
  • Thermoplastic enclosure, 5 in x 4 in x 1.3 in , Type 1, indoor use only, removable cover.
  • Indicator lights indicate power and alarm status.
  • Wall-mounted power supply, 120VAC, 50/60 Hz (input), 11.1VDC, 500mA maximum (output).