Camus
Dynaforce Series
The Dynaforce® has an efficiency rating of up to 99% and features a vertical cylindrical heat exchanger which is constructed entirely of stainless steel. The Dynaforce® is available for Hydronic Heating or Domestic Hot Water supply and can be fired with either natural gas or propane. Models range from 300,000 BTU up to 5 million BTU with a turndown ratio of up to 5:1.
Standard Features:
◦18 models available with inputs ranging from 300,000 btu/hr to 5 Mil btu/hr
◦Up to 99% Thermal Efficiency
◦Suitable for Category 2 and Category 4 installation
◦All welded heat exchanger, 316L headers, 439 tubes, counter flow, vertical cylindrical construction
◦Return water temperatures down to 40°F
◦Single point input adjustment for control of air and gas
◦1 to 1 air/gas ratio control for perfect combustion across entire modulation range
◦Extremely low NOx emissions (less than 9 ppm)
◦Flow Switch
◦Water pressure switch
◦Local/Remote switch for building management, remote modulation and set-point control
◦Extremely low noise level
◦Stainless steel mirror finish outer jacket
◦Advanced integrated Honeywell SOLA control with touch-screen interface
◦Suitable for venting with PVC, CPVC or PPE plastic vent material (app. dependent)
◦Cascade up to 8 individual appliances in daisy-chain formation
◦Direct ignition up to 2.5 million BTU/hr.
◦Proven pilot ignition for 3 to 5 million BTU/hr.
◦Low gas pressure switch
◦High Gas pressure switch (models 3000 through 5000)
◦Inlet regulator for incoming gas pressures up to 14” w.c.
◦Stainless steel burner with radial knitted fiber
◦Easy access to components for maximum serviceability
◦Maximum allowable working pressure of 160 psig
◦Maximum allowable discharge temperature of 210°F
◦Minimum gas pressure requirements of 4.5” w.c. for models 300-1000, 7” w.c. for models 1200-5000
◦Main burner test firing valve
◦For operation with natural gas or propane
◦Flame failure alarm contacts
◦5:1 turndown ratio with a minimum 20% firing rate
◦Flue temperature monitoring
Optional Features:
◦Dual Fuel for firing with natural and propane (incl. two gas trains)
◦Pump delay up to 1hp/Pilot duty over 1hp
◦Air inlet damper and/or damper contacts
◦Low water cut off (manual or automatic reset)
◦High gas pressure switch (standard on models 3000-5000)
◦Status on/off monitoring contacts
◦Gateway protocol converter for BACnet, Metasys N2, IP or LonWorks
◦Neutralization kit for condensate water
◦Remote operation for set-point or fire-rate control utilizing 0-10VDC
◦Additional Voltages